Oaklyn Borough
Certificate of Occupancy
Required- Certificate
- Certificate of Compliance (exterior housing code and property area inspection on sale)
- Issued by
- Borough of Oaklyn Administrative Office of Code Enforcement (Housing Code Department)
- Requirements
- Exterior housing code inspection and exterior property area inspection on every sale or resale
- Sidewalks, walkways, driveways and driveway aprons made safe: no cracks, raised walkways or deteriorated concrete (asphalt or macadam for driveways only, not aprons or sidewalks)
- Handrails where there are three or more steps; steps 30 inches above grade need a handrail on one side; 2 inch round handrails returned to post, with no more than 4 inch spindle spacing
- Railings on porch or stoop perimeters that have none, with no more than 4 inch spindle spacing
- Peeling, chipping or unpainted exterior surfaces scraped and painted
- Broken window panes repaired
- Open electrical splices or improperly installed fixtures corrected
- Gutters and downspouts hooked up and in place
- Any obvious hazardous and maintenance conditions
- Repairs the Code Enforcement office finds necessary must be completed within 30 days of notice
- Sump pump must not be connected to the sanitary sewer; Public Works inspects before settlement
- Fees
Housing code exterior inspection on sale (covers all inspections and reinspections) $50 - Valid for
- 90 days, provided the seller has not changed (2018 borough form)
- Phone
- 856-858-2457
Smoke and CO alarm certificate
Required- Requirements
- Smoke alarms by construction date: pre-1975 homes need 10-year sealed battery alarms on each level including the basement; newer homes need AC powered interconnected alarms per the era table on the form
- Smoke alarms on every level, outside sleeping areas, and at the bottom of basement stairwells
- All smoke alarms must be less than 10 years old; someone must take them down and check the date on the back, and undated alarms must be replaced
- Low voltage (alarm company) fire alarm systems must be tested by an alarm contractor before the inspection, with the certification shown to the inspector
- CO alarm outside of but within 10 feet of all sleeping areas if the home has a fuel burning appliance, fireplace or garage; CO alarms must be less than 7 years old
- House numbers: Arabic numerals at least 3 inches tall, contrasting, mounted at least 60 inches above ground and visible from the street
- Secondary power source warning label (wording like 'CAUTION MULTIPLE SOURCES OF POWER', not handwritten) within 18 inches of the main electrical panel and meter if there is a generator, solar panels or battery storage
- Everything must be done before the inspector arrives; an adult (18+) must be present at the start of the time block
- Oaklyn ordinance (2018 borough form): smoke alarms on every floor and in every bedroom; 10-year sealed battery alarms required since 1/1/19
Last checked October 20, 2026
Other towns in Camden County
- Audubon Borough
- Audubon Park Borough
- Barrington Borough
- Bellmawr Borough
- Berlin Borough
- Berlin Township
- Brooklawn Borough
- Camden City
- Cherry Hill Township
- Chesilhurst Borough
- Clementon Borough
- Collingswood Borough
- Gibbsboro Borough
- Gloucester City
- Gloucester Township
- Haddon Heights Borough
- Haddon Township
- Haddonfield Borough
- Hi-Nella Borough
- Laurel Springs Borough
- Lawnside Borough
- Lindenwold Borough
- Magnolia Borough
- Merchantville Borough
- Mount Ephraim Borough
- Pennsauken Township
- Pine Hill Borough
- Runnemede Borough
- Somerdale Borough
- Stratford Borough
- Tavistock Borough
- Voorhees Township
- Waterford Township
- Winslow Township
- Woodlynne Borough
Oaklyn Borough property taxes: typical bill, tax rate and appeal deadline