Certificate of Occupancy Required
Certificate of Compliance (exterior housing code and property area inspection on sale) · Borough of Oaklyn Administrative Office of Code Enforcement (Housing Code Department)
- Exterior housing code inspection and exterior property area inspection on every sale or resale
- Sidewalks, walkways, driveways and driveway aprons made safe: no cracks, raised walkways or deteriorated concrete (asphalt or macadam for driveways only, not aprons or sidewalks)
- Handrails where there are three or more steps; steps 30 inches above grade need a handrail on one side; 2 inch round handrails returned to post, with no more than 4 inch spindle spacing
- Railings on porch or stoop perimeters that have none, with no more than 4 inch spindle spacing
- Peeling, chipping or unpainted exterior surfaces scraped and painted
- Broken window panes repaired
- Open electrical splices or improperly installed fixtures corrected
- Gutters and downspouts hooked up and in place
- Any obvious hazardous and maintenance conditions
- Repairs the Code Enforcement office finds necessary must be completed within 30 days of notice
- Sump pump must not be connected to the sanitary sewer; Public Works inspects before settlement
| Housing code exterior inspection on sale (covers all inspections and reinspections) | $50 |
Smoke and CO alarm certificate Required
- Smoke alarms by construction date: pre-1975 homes need 10-year sealed battery alarms on each level including the basement; newer homes need AC powered interconnected alarms per the era table on the form
- Smoke alarms on every level, outside sleeping areas, and at the bottom of basement stairwells
- All smoke alarms must be less than 10 years old; someone must take them down and check the date on the back, and undated alarms must be replaced
- Low voltage (alarm company) fire alarm systems must be tested by an alarm contractor before the inspection, with the certification shown to the inspector
- CO alarm outside of but within 10 feet of all sleeping areas if the home has a fuel burning appliance, fireplace or garage; CO alarms must be less than 7 years old
- House numbers: Arabic numerals at least 3 inches tall, contrasting, mounted at least 60 inches above ground and visible from the street
- Secondary power source warning label (wording like 'CAUTION MULTIPLE SOURCES OF POWER', not handwritten) within 18 inches of the main electrical panel and meter if there is a generator, solar panels or battery storage
- Everything must be done before the inspector arrives; an adult (18+) must be present at the start of the time block
- Oaklyn ordinance (2018 borough form): smoke alarms on every floor and in every bedroom; 10-year sealed battery alarms required since 1/1/19
Regional Fire Prevention Alliance (run by Barrington Borough)
| Request received 14+ business days before change of occupant | $66.00 |
| Request received 8-13 business days before | $74.00 |
| Request received 4-7 business days before | $106.00 |
| Request received 3 business days or less before | $171.00 |
| Reinspection after a failed inspection | $50.00 |
| Penalty for change of ownership or occupancy without the certificate | $500 |