Districts 1, 2, 4 and 5: CO alarms must be less than 7 years old
Districts 1, 4 and 5: smoke alarms older than 10 years not accepted; battery alarms must be 10-year sealed (hardwired exempt); hardwired alarms cannot be replaced with battery alarms
Basement smoke alarm at the bottom of the stairwell on the ceiling (not between joists); hallway alarms within 10 feet of all bedroom doors
House numbers at least 4 inches high, contrasting color, permanently on the house and visible from the street (mailbox or light post numbers not accepted)
Homes with a secondary power source (solar, generator, battery storage) need a non-handwritten 'CAUTION: MULTIPLE SOURCES OF POWER' label within 18 inches of the main electrical panel and the electric meter
District 5 checklist: alarm type follows the year the house was built (for example 1991 to present: hardwired interconnected alarms with battery backup on every level and in each bedroom)
Current 2025-2026 district forms do not list a fire extinguisher (District 6's 2026 affidavit title still says 'Portable Fire Extinguisher' but its checklist has no extinguisher item)
Gloucester Township Fire District #1 Bureau of Fire Prevention (Glendora Fire Company)
Fire District #1 (Glendora area). Check the property's fire district in the 'Special Taxing Districts' block at https://wipp.edmundsassoc.com/Wipp/?wippid=0415
Fees
10 or more business days before settlement
$45.00
4 to 9 business days before settlement
$90.00
Less than 4 business days before settlement
$161.00
Re-inspection or failure to appear
$45.00
Timing
10 or more business days before settlement for the lowest fee