Pittsgrove Township
Certificate of Occupancy Required
Continuing Certificate of Occupancy (CCO) · Housing/Zoning/Code Enforcement Office
- Smoke detectors in each bedroom, within 10 feet of bedroom areas and at least one per level including the basement and walk-up attic; battery units must be 10-year sealed
- CO detectors within 10 feet of bedroom areas and kitchens, at least one per level including basements and walk-up attics
- Fire extinguisher rated 2A:10BC, no more than 10 pounds, visibly mounted in the kitchen or within 10 feet of it toward an exit
- 911 post (4 x 4 inch, 6 feet, 2 feet in the ground) at the driveway entrance with 4-inch reflective numbers on each side
- Tree limbs cut back at least 10 feet from the roof line
- Handrails on stairways and stoops with 3 or more steps; guardrails on porches, decks and raised floors 30 inches or higher, spindles no more than 4 inches apart
- No broken windows or doors, no holes in walls, no exterior damage or leaking roof
- Switch plates and outlet covers in place, GFI outlets within 3 feet of kitchen and bathroom sinks, no bare wires, secure covered breaker panel
- Working range with anti-tip device and other appliances working
- Hot and cold running water without leaks, flushing toilets and working heat
- Bathroom window or exhaust fan vented outside; water heater relief valve extension within 6 inches of the floor
- Electric service wire and meter sound; no double-cylinder deadbolts on exterior doors
- All code violations abated and all open construction, electrical, plumbing or fire permits closed
- No rubbish or debris inside or out; all utilities on at the inspection
- No more than 2 occupants per bedroom
| Continuing Certificate of Occupancy inspection (paid in advance) | $40.00 |
| Re-inspection (payable before or at the re-inspection) | $15.00 |
- Phone: 856/358-2300 ext 6029
- Timing: Inspection fee is paid in advance. The application is void after 45 days.
- Application: https://web.archive.org/web/20240630050032/https://www.pittsgrovetownship.com/wp-content/uploads/2022/10/Application-and-Requirements-for-Continuing-Certificate-of-Occupancy-PDF.pdf
Smoke and CO alarm certificate Required
- Township CCO smoke sheet (effective January 1, 2019): battery smoke detectors must be 10-year sealed battery units
- Smoke detectors in each bedroom as well as on each level (Township CCO list)
- CO detectors within 10 feet of bedroom areas and kitchens, one per level (Township CCO list)
- Township CCO list still asks for a 2A:10BC fire extinguisher, no more than 10 pounds, mounted in or within 10 feet of the kitchen
Pittsgrove Township Bureau of Fire Safety (smoke detector compliance through the Pittsgrove Township Zoning Office)
- Phone: 856-358-2300
- Official page: https://www.pittsgrovetownship.com/departments/housing-zoning-code-enforcement/