Resale CO checklist
Red Bank Borough
Monmouth County, New Jersey · Checked October 4, 2026
Certificate of Occupancy Required
Certificate of Occupancy on sale or transfer (Property Maintenance Code Section 102.1A); not required for owner-occupied single-family sales · Borough of Red Bank Department of Code Enforcement (Fire Marshal's Office)
- Applies to the sale or transfer of 2-family homes and of single-family homes that will not be owner-occupied; owner-occupied single-family sales need only the smoke/CO certificate
- Compliance inspection under the International Property Maintenance Code (address numbers at least 4 inches, no double cylinder locks, heating and water heater safety, garage fire door, floors, roof, range, plumbing)
- All open permits must have a final inspection before a C.O. can be issued
- Smoke and carbon monoxide certificate (CSDCMAC)
- A conditional C.O. may be issued for owner-occupied 2- or 3-unit buildings if all defects are disclosed to the buyer and conditions are met
| C.O. on sale or transfer, one- or two-family dwelling (per dwelling unit) | $100 |
| Reinspection after second reinspection and failure, residential | $50 |
- Phone: 732-530-2764
- Timing: The owner must give at least 14 calendar days notice to Code Enforcement for the compliance inspection.
- Good for: A certificate issued within the prior six months can be reused (a copy of the prior certificate suffices).
- Official page: https://www.redbanknj.org/183/Fire-Marshals-Office
Smoke and CO alarm certificate Required
- Ten-year sealed battery smoke alarms or A/C powered hardwired smoke detectors in each bedroom and on each level within ten feet of the bedrooms (basement, first floor, second floor), excluding crawl spaces and unfinished attics
- Smoke detectors properly mounted (ceiling at least 4 inches from the wall; wall mount 4 to 12 inches from the ceiling), UL listed with a test button; A/C powered alarms may not be replaced with battery units
- Carbon monoxide alarm on each level within ten feet of the bedrooms (battery, plug-in or part of a central station system), UL listed
- Central station fire alarms need a letter from the monitoring company that the system works
- An adult (18 or older) must be present; pets secured
- Fire extinguisher no longer required (Fire Marshal's 2026 handout, citing the February 2025 change)
Red Bank Fire Marshal's Office (Fire Prevention)
| CSDCMAC, request more than 10 business days before change of occupant | $100 |
| Request four to 10 business days before | $125 |
| Request fewer than four business days before | $150 |
- Phone: 732-530-2764
- Timing: Fee depends on business days before the change of occupant: more than 10 business days for the lowest fee. Inspections are done 10 a.m. to 2 p.m., Monday to Friday.
- Official page: https://www.redbanknj.org/183/Fire-Marshals-Office