Town page
WatchdogResale CO checklist

Edison Township

Middlesex County, New Jersey · Checked September 30, 2026

Certificate of Occupancy Required

Residential Resale Certificate (Edison Certificate for Change of Ownership/Tenancy) · Code Enforcement, Township of Edison

  • Smoke certificate from Fire Prevention must be issued before the Resale Certificate
  • Check for open permits; any work that needed a permit must get a compliance permit, be inspected and closed
  • Additions, alterations, finished basements or attics, garage conversions, patios, decks, pools and spas must have zoning and building approvals
  • Pool or spa: fence and childproof gate required
  • Handrails and guardrails secure and proper height; stair riser openings under 4 inches
  • Water heater, furnace, air conditioner and boiler installed with permits and working
  • Water heater: pressure relief valve, bonding cable, relief pipe (not black pipe) ending 6 inches from the floor, unthreaded
  • Oil and gas flue connections secure; gas appliances have shut-off valves
  • Clothes dryer vented outside
  • No openings in garage ceilings or walls next to living space
  • House numbers on the front of the house, at least 4 inches high
  • Existing GFI outlets working
  • No junk or debris in basement, attic or yard
  • No keyed locks on bedrooms; exit doors without a keyed inside lock
  • No imminent hazards
Residential Resale Certificate (1 or 2 family)$150

Smoke and CO alarm certificate Required

  • Battery smoke alarms must be 10 year sealed battery type; existing hardwired alarms cannot be replaced with battery alarms
  • Smoke alarms no more than 10 years old
  • Smoke alarm on every level including the basement (3 or more steps counts as a separate level), within 10 feet of bedroom doors; basement alarm on the ceiling or beam at the base of the stairs; finished loft or attic living space needs an alarm
  • Alarm type follows the year the house was built (hardwired and interconnected rules for homes built after 1977, and alarms in each bedroom for homes built from March 1991)
  • CO alarm within 10 feet of sleeping areas; a bedroom with a fuel burning appliance needs its own CO alarm; bring the CO alarm instructions to the inspection
  • Secondary power sources (solar, battery storage, installed generator) must be labeled per P.L.2025, c.19
  • Supervised or monitored alarm systems must be kept working at change of occupancy

Edison Division of Fire, Bureau of Fire Prevention (Fire Marshal's Office)

Request received more than 10 alternating business days before inspection$60.00
Request received 5 to 10 alternating business days before inspection$90.00
Request received 1 to 4 alternating business days before inspection$140.00
Failure to appear for a scheduled appointment without notice$50.00
Re-inspection after a failed inspection$20.00
Demolition letter$25.00