Resale CO checklist
Mount Ephraim Borough
Camden County, New Jersey · Checked October 20, 2026
Certificate of Occupancy Required
Resale Certificate of Occupancy (Certificate of Continued Occupancy) · Borough of Mount Ephraim Construction / Zoning / Code Enforcement Office (Enforcement Officer is the Construction Code Official or designee)
- Visible 911 house number, at least 4 inches tall, visible from the street
- Sidewalks safe and free of hazards; no raised sidewalks or deteriorated concrete
- Driveways and aprons: asphalt or macadam only for driveways; a deteriorated asphalt apron must be replaced with concrete
- Handrails where there are three or more steps; steps 30 inches above grade need handrails on both sides; no more than 4 inch spacing between spindles
- Porches with no perimeter railings must have railings installed (no more than 4 inch spindle spacing)
- Peeling or chipping exterior paint scraped and repainted; unpainted exterior surfaces painted
- Broken window panes repaired
- Exterior electrical open splices or improperly installed fixtures corrected
- Gutters and downspouts properly installed
- Any hazardous condition the inspector finds must be corrected
- Work done without permits may be cited and must be permitted and inspected
- Open permits must be closed out (final inspections passed and certificate obtained)
- Separate smoke alarm / CO alarm certificate from the Regional Fire Prevention Alliance before settlement
| Single family dwelling resale CO (2026 application) | $120.00 |
| Reinspection (2026 application) | $25.00 |
| Reinspection fee in town code, 1-2 family residences under 5,000 sq ft (Ord. 2024-15; differs from the $25 on the form) | $50 |
Smoke and CO alarm certificate Required
- Smoke alarms by construction date: pre-1975 homes need 10-year sealed battery alarms on each level including the basement; newer homes need AC powered interconnected alarms per the era table on the form
- Smoke alarms on every level, outside sleeping areas, and at the bottom of basement stairwells
- All smoke alarms must be less than 10 years old; someone must take them down and check the date on the back, and undated alarms must be replaced
- Low voltage (alarm company) fire alarm systems must be tested by an alarm contractor before the inspection, with the certification shown to the inspector
- CO alarm outside of but within 10 feet of all sleeping areas if the home has a fuel burning appliance, fireplace or garage; CO alarms must be less than 7 years old
- House numbers: Arabic numerals at least 3 inches tall, contrasting, mounted at least 60 inches above ground and visible from the street
- Secondary power source warning label (wording like 'CAUTION MULTIPLE SOURCES OF POWER', not handwritten) within 18 inches of the main electrical panel and meter if there is a generator, solar panels or battery storage
- Everything must be done before the inspector arrives; an adult (18+) must be present at the start of the time block
Regional Fire Prevention Alliance (run by Barrington Borough)
| Request received 14+ business days before change of occupant | $66.00 |
| Request received 8-13 business days before | $74.00 |
| Request received 4-7 business days before | $106.00 |
| Request received 3 business days or less before | $171.00 |
| Reinspection after a failed inspection | $50.00 |
| Penalty for change of ownership or occupancy without the certificate | $500 |