Town page
WatchdogResale CO checklist

Clementon Borough

Camden County, New Jersey · Checked October 20, 2026

Certificate of Occupancy Required

Certificate of Continued Occupancy (CCO) for a Residential Resale · Borough of Clementon Code Enforcement Office

  • House number at least 4 inches high, visible from the street
  • Steps and walkways without trip hazards; cracked sidewalk blocks with a height change replaced
  • Guardrails where a porch, landing or stairs is over 30 inches above grade; handrail on steps with 4 or more risers
  • Yard free of high grass, weeds, dead trees, debris and hazards
  • Gutters and downspouts attached and clear, with splash blocks or diverters
  • Basement/crawl space openings and exterior doors secure and weatherproof; sump pump discharge outside, not into the sanitary sewer
  • No signs of pests (otherwise a licensed pest control certification is needed)
  • Bathroom window or exhaust fan; GFI protection on existing bathroom, kitchen counter, garage and exterior outlets
  • Cover plates on all switches and outlets; electrical panel secure, labeled, no open breaker slots; A/C disconnect at the outdoor unit
  • Windows intact; bedroom windows open and close for emergency escape
  • Water heater relief valve with discharge pipe ending 2 to 6 inches above the floor; tight flue connections
  • No plumbing leaks; fixtures and toilets secure
  • Heating system working
  • Work done without permits will be cited; open permits must be closed out
1 and 2 family house or condo ($60 / $120; form does not say which applies to which, likely $60 for one unit and $120 for two)$60/$120
3 and 4 family house, per unit$60 per unit
Reinspection$30

Smoke and CO alarm certificate Required

  • Working smoke alarm installed per NFPA 74 and N.J.A.C. 5:70-4.19, listed to ANSI/UL 217, following the Borough's requirement chart
  • All single-station smoke alarms must be 10-year sealed battery alarms (effective January 1, 2019); AC-powered alarms from original construction cannot be replaced with battery alarms
  • Working carbon monoxide alarm outside each separate sleeping area, in the immediate vicinity of the bedrooms
  • Homes with a secondary power source (generator, solar panels, battery storage) need a Secondary Power Source Identification Label within 18 inches of the main electrical panel and electric meter (ANSI Z535.4)
  • Visible address in numbers or letters at least 3 inches high, contrasting color, on the street side

Borough of Clementon Bureau of Fire Safety

Request received more than 10 business days before change of occupant$60
Request received 4 to 10 business days before$100
Request received 2 to 4 business days before$161
Same day of settlement and/or one day$200
Re-inspection after a failed initial inspection$35