Pemberton Township
Certificate of Occupancy Required
Certificate of Occupancy Transfer (Resale Application / housing inspection) · Pemberton Township Code Enforcement Division (Housing Code Official), Department of Community Development
- House number on the dwelling, reflective, at least 3.5 inches high and readable from the street
- Fences and pool areas with self-latching, outward-swinging gates (fence at least 48 inches, latch at least 54 inches)
- Landings and porches 30 inches or higher need a guard rail at least 36 inches high with openings no wider than 4 inches
- Stairways, decks, porches and balconies structurally sound; handrail on any stair with 4 or more risers
- No broken or missing glass; windows open, lock and have screens; egress windows open easily
- Basement outside entrances kept tight against pests and water
- Anti-tilt device on the stove; all utilities on at the time of inspection
- Smoke alarm on every level, in every bedroom and outside each sleeping area (form says battery operated)
- Carbon monoxide alarm near sleeping areas if the home has a fuel-burning appliance or attached garage
- ABC fire extinguisher, 5 to 10 lb, mounted in a visible, convenient spot (April 2026 form still lists it)
- Bathroom window or exhaust fan vented outside
- Mechanical equipment (exhaust fans, sump pumps, wood stoves, fireplaces) safe and working
- No electrical hazards: no open junction boxes, taped splices or extension-cord wiring; service wire in sound condition
- GFCI protection for pools, spas, exterior and garage outlets, within 5 feet of water, and at kitchen and bath counters
- Certifications may be required for roof, electrical, structural or heating items
| Resale inspection (initial inspection) | $150.00 |
| Each reinspection | $50.00 |
- Phone: 609-894-3376
- Good for: The application expires 60 days after it is filed and cannot be transferred. How long the certificate itself is valid is not stated.
- Application: https://www.pemberton-twp.com/04.29.26%20Resale%20Application.pdf?t=202605041545530
Smoke and CO alarm certificate Required
- Smoke alarm on every level, in every bedroom and outside each sleeping area
- Carbon monoxide alarm near sleeping areas (homes with a fuel-burning appliance or attached garage)
- ABC fire extinguisher, 5 to 10 lb, mounted in a visible, convenient location (still on the April 2026 township checklist)
Not confirmed. Likely Pemberton Township Code Enforcement Division, which checks smoke alarms, CO alarms and the extinguisher during the Certificate of Occupancy Transfer inspection
- Phone: 609-894-3376
- Official page: https://www.pemberton-twp.com/departments/community_development/code_enforcement_division/index.php