Certificate of Occupancy Required

Certificate of Resale (certificate of occupancy / continued certificate of occupancy on resale of a residential dwelling) · Borough of River Edge Building Department (Construction Official)

  • Seller must close out all permits before the CO inspection
  • Smoke detector on every level including the basement and within 10 feet of every bedroom door; type depends on the year built or altered (battery before 1977, hardwired/interconnected for later homes); detectors over 10 years old must be replaced; electric detectors cannot be replaced with battery units
  • Monitored smoke detection systems need an NFPA-72 test report from the monitoring company dated no more than 30 days before closing
  • Carbon monoxide detector on every level and on the sleeping levels of 1 and 2 family dwellings, in the hallway within 10 feet of every bedroom door
  • Portable fire extinguisher within 10 feet of the kitchen: 2.5 to 10 pounds, 2A-10B:C (ABC), tagged within the past year or new with receipt, mounted with top no more than 5 feet up, owner's manual present (checklist revised 08/28/2019 still lists it)
  • Homes with a residential sprinkler system need an inspection report from a licensed contractor
  • Sump pumps may not discharge into a sewer line or sink; handrails on interior and exterior stairs; no extension cords as permanent wiring
  • Sidewalks in disrepair must be repaired or replaced before inspection (sidewalk permit needed to replace slabs)
  • Common hallways and stairways in two-family houses need smoke detectors on each level
Continued certificate of occupancy (resale), Use Groups R-3, R-4 and R-5 (one- and two-family homes) (Borough code 206-2Q)$100
Certificate of continued occupancy, structure Use Group R-2, R-3, R-4 or R-5 (construction code fees, Borough code 206-2I)$75
Certificate of continued occupancy, each added dwelling unit (Borough code 206-2I)$35

Smoke and CO alarm certificate Required

  • Smoke detectors on all levels including the basement and within 10 feet of every bedroom door, per the year the house was built or altered
  • Smoke detectors over 10 years old must be replaced; electric detectors may not be replaced with battery units
  • Carbon monoxide detector in the hallway within 10 feet of every bedroom door, on every level of 1 and 2 family dwellings
  • Portable fire extinguisher (2A-10B:C, 2.5 to 10 lb) within 10 feet of the kitchen, serviced within a year or new with receipt (checklist still lists it)

River Edge Building Department (smoke/CO/extinguisher checked during the Certificate of Resale inspection); River Edge Fire Prevention Bureau handles rentals

Continued certificate of occupancy (resale), Use Groups R-3, R-4 and R-5 (one- and two-family homes) (Borough code 206-2Q)$100