Certificate of Occupancy Required

Certificate of Compliance (COC), also called Certificate of Occupancy; Pre-Occupancy Inspection for sales · Zoning Office / Housing Office (Zoning & Housing Official)

  • House numbers 5 inches high and visible from the street
  • GFI protected outlets within 6 feet of a water source and on all exterior outlets
  • Fire extinguisher mounted in the kitchen
  • Appliances installed properly and working, no extension cords; exhaust fan over the stove (ductless hood allowed) and anti-tip bracket on the stove
  • Adequate electric, heating and plumbing service; two separate outlets in each habitable room
  • Bathroom vented or with a working window
  • Screened window in each room; all windows working with locks; exterior doors and hardware working
  • Handrails on steps with more than 3 risers; rails around landings or porches 30 inches or higher
  • Water heater relief valve piped to within 6 inches of the floor; emergency shut-off at the top of the stairs for a basement heater
  • Pools over 125 square feet and 3 feet or higher need a fence at least 4 feet high with a self-latching gate
  • House free of insect infestation
  • Smoke/CO inspection must pass (separate Bureau of Fire Prevention certificate)
  • Private well homes must comply with the Private Well Testing Act before sale; homes on a cesspool or privy cannot be sold until it is replaced with an approved system
Pre-Occupancy Inspection, sales$25
Re-inspection (if needed)$25

Smoke and CO alarm certificate Required

  • 10-year sealed battery alarms or hardwired alarms on every level of the dwelling; an alarm at the bottom of the basement stairwell at ceiling level
  • Alarms in the hallways within 10 feet of all bedrooms, and a smoke alarm in every bedroom
  • Smoke and CO alarms must be UL listed, less than 10 years old, working and installed per the maker's instructions; plug-in, battery or hardwired alarms are allowed, but hardwired alarms cannot be replaced with battery alarms
  • Do not plug alarms into switched outlets or outlets at the floor molding
  • A low-voltage fire alarm system must be tested and approved by an alarm contractor before the inspection; show the alarm certification to the inspector
  • House numbers at least 4 inches high, contrasting color, permanently fixed and visible from the street
  • Homes with solar, a generator or battery storage need a permanent printed label (wording like "Caution: Multiple Sources of Power") at the main electrical panel and the electric meter
  • The Township Housing CO checklist (separate from this form) still lists a fire extinguisher mounted in the kitchen

Township of Upper Pittsgrove Bureau of Fire Prevention

Smoke and carbon monoxide alarms inspection application$25.00
Re-inspection for a failed or no-show inspection (same as the initial inspection fee)$25.00