Westville Borough
Certificate of Occupancy Required
Certificate of Inspection (Residential) · Borough of Westville Housing & Code Enforcement
- Remove trash and debris inside and outside
- Fix tripping hazards on sidewalks, walkways, steps and driveway
- Cut high grass and weeds; no standing water
- Exterior in good repair: siding, roof, flashing, gutters, foundation; scrape and paint peeling paint
- Address numbers visible from the street
- Handrail on steps with 3 or more risers; guardrails where the drop is 30 inches or more
- Windows open and stay open, with tight screens and no broken glass
- Bedrooms need two ways out (a door and a window)
- Bathrooms need a window or an exhaust fan vented outside
- Plumbing, heating and electrical safe and working; appliances on grounded outlets
- Water heater gives at least 120 degree water and has a discharge pipe ending 2 to 6 inches from the floor
- GFCI outlets at kitchen sink, utility sinks, bathrooms, sump pumps and outside
- Work done without permits must get permits and pass final inspection
- Proof of extermination if there are signs of insects or rodents
- Smoke alarms, CO alarms and a fire extinguisher (see fire certificate section)
| Certificate of Inspection, per unit | $100 |
| Re-inspection, 1st | $50 |
| Re-inspection, 2nd | $60 |
| Re-inspection, 3rd | $75 |
| Re-inspection, 4th and later, per unit | $100 |
- Phone: 856-456-0030 option 5
- Timing: Schedule as far in advance as possible (the Borough says to allow about one week for scheduling).
- Application: https://westville-nj.com/wp-content/uploads/2026/03/CERTIFICATE-OF-INSPECTION-RESIDENTIAL-APPLICATION.pdf
Smoke and CO alarm certificate Required
- Smoke alarms (hardwired or 10-year sealed) must be less than 10 years old; locations that are hardwired must keep hardwired alarms
- Smoke alarm on each level including the basement, within 10 feet outside bedrooms, and in every room used for sleeping
- CO alarms (hardwired or battery) less than 10 years old, within 10 feet of each room used for sleeping
- Fire extinguisher rated 2A:10B:C for residential use, within 10 feet of the kitchen on the way out, mounted no higher than 5 feet with its original hardware, not blocked
- Low-voltage (monitored) smoke alarm systems need a letter from the alarm company showing a test in the last 30 days
Westville Fire District #1 (Office of the Fire Marshal)
- Phone: 856-456-9432
- Official page: https://westvillefd.com/fire-district-contacts/