Town page
WatchdogResale CO checklist

South Orange Village

Essex County, New Jersey · Checked October 3, 2026

Certificate of Occupancy Required

Certificate of Continued Occupancy (CCO) · South Orange Fire Prevention Bureau (Fire Official), within the Building and Code Enforcement Department

  • Inspection by the Fire Official or inspector for compliance with N.J.A.C. 5:70-4.19 (smoke alarms, carbon monoxide alarms); smoke detector inspection is part of the CCO
  • Owner certifies all structures have valid zoning and building permits, registrations and certificates; the CCO verifies there are no open permits or violations unless a separate written agreement is attached
  • The CCO does not confirm zoning compliance; that needs a zoning verification letter, zoning permit or Certificate of Legal Nonconformity
  • No rubbish, debris or bulk garbage left on the property before the new occupancy
  • Application asks for buyer details, proposed closing date, realtor, room counts, accessory structures, house number visibility and any secondary power source (solar, generator, battery storage)
  • Secondary power source warning label within 18 inches of the main electric panel and meter, not handwritten
  • Monitored or low-voltage alarm systems need a current full NFPA 72 report from an alarm contractor or certified electrician
  • Someone must be at the property to give the inspector access (missed appointment fee otherwise)
CCO inspection, one-family$150.00
CCO inspection, two-family$200.00
CCO, single family or condo/townhouse (online application)$150
CCO, two-family (online application)$200
CCO first re-inspection$50.00
CCO second re-inspection$50.00
CCO third or later re-inspection$75.00
Expedited fee, request 5 to 10 business days before closing (added to inspection fee)$50
Expedited fee, request 4 or fewer business days before closing (added to inspection fee)$100
Missed appointment fee$50

Smoke and CO alarm certificate Required

  • Smoke alarms UL 217 listed, no more than 10 years old; standalone battery alarms must be 10-year sealed
  • Smoke alarms on each level and outside each sleeping area; hardwired, interconnected and in-bedroom alarms depending on the year the house was built
  • Hardwired alarms stay hardwired; basement alarm within 10 feet of the base of the stairs
  • Carbon monoxide alarm on each level, and on sleeping levels within 10 feet of bedroom doors; UL 2034; battery, plug-in or hardwired
  • Secondary power source label within 18 inches of the main electric panel and meter
  • Monitored or low-voltage fire alarm systems need a current full NFPA 72 report

South Orange Fire Prevention Bureau

Smoke detector compliance certificate fee (Village Code 157-12F)$50.00