Resale CO checklist
Berlin Borough
Camden County, New Jersey · Checked October 20, 2026
Certificate of Occupancy Required
Certificate of Continued Occupancy (CCO) · Borough of Berlin Construction Department (Borough Housing Inspector under the code)
- All utilities on for the inspection; lockbox code if vacant
- Trash and debris cleared inside and out
- Walkways level and free of trip hazards
- 4 inch contrasting house number visible from the street
- Graspable handrail on steps with more than four risers; guardrails on both sides of open stairs
- Windows and doors operable, no cracked or broken glass
- No pest or rodent infestation
- Egress window or door in every bedroom; no bedrooms in basements
- Bathroom window or exhaust fan
- Dryer vent hard piped to the outside
- Water heater discharge pipe ending 2 to 6 inches above the floor
- Mechanical equipment kept clear of combustible materials
- Smoke detectors working on every level, under 10 years old, 10-year sealed battery if battery powered, hardwired units interconnected and not swapped for battery units; any fire alarm system tested by a certified technician with a copy of the report
- CO detector within 10 feet of each bedroom
- Wood and metal surfaces free of deterioration or rust; walls intact; gutters and downspouts clean and working
- Pools, fences, garages and decks safe; pool gates self-closing and self-latching
- Wood-burning fireplace or stove needs a certificate showing it is in good working order
- Thumb-latch turn-style interior door locks
- All open permits closed with final inspections; unpermitted work must be documented (UCC Bulletin 06-1) before the CCO is issued
| Initial CCO inspection (application form) | $100 |
| Re-inspection (application form) | $50 |
| Initial inspection under Borough Code 256-25 as amended by Ord. 2025-12 (includes the CO or CCO and initial registration) | $200 |
Smoke and CO alarm certificate Required
- Battery smoke detectors must be 10-year sealed battery units (Bureau notice, 'Effective Immediately', July 2026)
- Smoke alarms on each level and outside each separate sleeping area
- Hardwired smoke alarms from original construction or rehabilitation may not be replaced with battery alarms
- CO alarms in the immediate vicinity of the sleeping areas if the home has a fuel-burning device or attached garage
- If the home has a monitored alarm system, notify the alarm company before the test and have the codes available at the inspection
Berlin Borough Bureau of Fire Prevention
| CSDCMAC, request received more than 10 business days before change of occupant | $45.00 |
| CSDCMAC, request received 4 to 10 business days before change of occupant | $90.00 |
| CSDCMAC, request received fewer than 4 business days before change of occupant | $161.00 |
| Additional fee if more than two visits are needed | $45.00 |