Resale CO checklist
Medford Lakes Borough
Burlington County, New Jersey · Checked October 13, 2026
Certificate of Occupancy Required
Certificate of Continuing Occupancy (CCO), issued after the extraneous flow (sump pump / roof drain / floor drain) inspection · Borough of Medford Lakes (Wastewater Department inspection; Office of Construction handles CCO questions)
- Sump pumps, roof drains, floor drains and other drainage devices must not be connected directly or indirectly to the Borough sanitary sewer; a CCO is issued only after any such connections are permanently removed (Code 190-26)
- Disconnected sump pumps and drains must discharge at least 10 feet from any structure with a basement, cellar or crawl space, not into a street, storm sewer, neighbor's property or lake without approval
- Smoke alarm, CO alarm and fire extinguisher inspection done together with the CCO inspection (see fire_cert)
| Extraneous flow (sump pump / roof / floor drain) inspection, Wastewater Department, more than 10 business days before settlement (no separate CCO fee was found) | $50 |
| Extraneous flow inspection, 4 to 10 business days before settlement | $70 |
| Extraneous flow inspection, less than 4 business days before settlement | $125 |
| Extraneous flow re-inspection | $35 |
| Cash bond if the work cannot be finished before closing (Borough then issues a temporary CCO; bond returned after approval) | $2,000 |
Smoke and CO alarm certificate Required
- House numbers: numerals at least 4 inches high, contrasting color, permanently fixed to the house and visible from the street; light post or mailbox numbers are not accepted
- Smoke alarm on every level; basement alarm at the bottom of the stairwell at ceiling level (not between joists); hallway alarm within 10 feet of all bedroom doors
- Smoke alarm on the ceiling of every bedroom in homes built 1991 to present
- Hard-wired smoke alarms cannot be replaced with battery alarms; all smoke alarms under 10 years old and working; battery alarms must be the 10-year battery type
- CO alarm in the hallway within 10 feet of all bedrooms, under 10 years old, installed per the maker; plug-in, battery or hard-wired accepted, but not in switched outlets or against floor molding
- Fire extinguisher still on the October 2024 form: minimum 2A-10B:C, under 10 pounds, mounted on its bracket within 10 feet of the kitchen in the exit path, visible and reachable
- Homes with a low voltage fire alarm system must have it tested and approved by the alarm company before the inspection and show the alarm certification at the inspection
Borough of Medford Lakes Fire Department, Bureau of Fire Prevention (LEA #03321)
| More than 10 business days before settlement | $50 |
| 4 to 10 business days before settlement | $70 |
| Less than 4 business days before settlement | $125 |
| Re-inspection | $35 |