Resale CO checklist
Oakland Borough
Bergen County, New Jersey · Checked November 3, 2026
Certificate of Occupancy Required
Certificate of Approval for Occupancy (CAO), formerly called CCO · Borough of Oakland Fire Prevention Bureau / Code Enforcement Department, with Board of Health, Building Department and Code Enforcement sign-offs
- Complete application (owner, buyer or realtor), with a secondary mailing address, phone and email for the buyer and phone and email for the seller
- All open building permits and property maintenance violations must be closed before the CAO (and before a fire inspection can be set up)
- Board of Health sign-off: septic reports, sewer information, well water reports; cesspools must be upgraded at realty transfer
- Fire certificate (smoke alarms, CO alarms, fire extinguisher, house numbers)
- Building inspection only if the fire inspector sees a construction code concern (for example water heater and boiler relief pipes within 6 inches of the floor, holes in garage ceiling, extension cords used as permanent wiring)
| Certificate of Approval for Occupancy, sale of single or two family home (includes realtor sign fee and Board of Health review fee) | $115 |
| CAO extension, 30 days | $30 |
- Phone: 201-337-8111 ext. 2025
- Timing: Submit at least 30 days before closing; can be filed as soon as the house has a buyer
- Good for: The application is valid for 6 months from the application date; approvals expire 90 days from the signature date. After the fire certificate is issued the applicant has 90 days to complete the CAO ($30 for a 30-day extension).
- Application: https://www.govpilot.com/forms/main/8ba7ec97-ae8/CAO-Residential/Borough-of-Oakland/NJ/7004/0
Smoke and CO alarm certificate Required
- Smoke detectors on each level, including the basement, and within 10 feet of each separate sleeping area; hardwired or 10-year sealed battery; any detector older than 10 years must be replaced
- Hardwired alarms from original construction stay hardwired (no battery-only replacement)
- Carbon monoxide detectors within 10 feet of each separate sleeping area (battery, hardwired or plug-in, UL 2034)
- Low voltage (monitored) alarm systems not part of original construction must have been tested in the year of sale with an NFPA 72 report
- One fire extinguisher, 2A:10B:C, no more than 10 lbs, within 10 feet of the kitchen in the exit path, top no more than 5 feet above the floor, serviced and tagged in the past 12 months or with a recent purchase receipt (form still lists it)
- House numbers in a contrasting color, 3 inches high, permanently affixed and clearly visible near the front door
- All building permits and property maintenance violations closed before the fire inspection is scheduled
Oakland Fire Prevention Bureau
| Fire certificate, sale of single or two family home | $85 |
| Expedite fee | $50 |
| Re-inspection fee | $50 |