Resale CO checklist
Northfield City
Atlantic County, New Jersey · Checked October 6, 2026
Certificate of Occupancy Required
Certificate of Compliance for the Resale of One and Two Family Dwellings (CCO) · City of Northfield Housing Officer (Housing and Zoning)
- Smoke alarms and carbon monoxide alarms in good working order, placed by the year the home was built (see fire certificate)
- Portable ABC fire extinguisher near the kitchen (packet still lists it; see fire certificate)
- Heating certification for every oil or gas fired heating unit, from a NJ licensed plumber or HVAC contractor
- Sidewalks, walkways, stairs, driveways and parking areas in good repair
- Yard free of weeds; garages, fences and other accessory structures sound
- Pools clean; pools, hot tubs and spas over 24 inches deep fenced at least 48 inches high with self-closing, self-latching gates
- Exterior wood painted or protected; house number plainly visible from the street
- Roof, flashing, gutters and downspouts sound and draining properly
- Windows that open can be held open; every habitable room has at least one openable window
- Interior in good repair, sanitary, and free of rubbish or garbage
- Bathroom window or mechanical exhaust vented outdoors
- Heat provided; at least two outlets in each habitable room, a bathroom outlet, a laundry outlet, cover plates on all outlets, GFCI protection within 4 feet of water (if remodeled)
- Fences, decks, sheds, pools and similar items built without zoning or construction permits delay the certificate until corrected
| Resale CCO application and inspection, non-refundable | $85.00 |
| Re-inspection due to violations | $25.00 |
| Settlement 5 days or less after application (may apply) | $10 |
Smoke and CO alarm certificate Required
- Smoke alarms by year built (City packet): before January 1977 battery alarms on each level including the basement and within 10 feet of bedrooms; later homes A/C powered (hardwired), interconnected from August 1984, and from March 1991 A/C powered with battery backup on each level and inside each bedroom
- Ten-year sealed battery single station smoke alarms where no alarms exist or when replacing battery alarms; hardwired alarms from original construction or a rehab project may not be replaced with battery alarms
- Replace smoke alarms 10 years from manufacture or when they fail tests; replace combination smoke/CO alarms at the end-of-life signal or 10 years
- Carbon monoxide alarm within 10 feet of bedroom doors; bedrooms with fuel burning appliances also need a CO alarm
- Portable fire extinguisher (form still lists it): minimum 2A-10B:C, no more than 10 pounds, within 10 feet of the kitchen in the path of egress, mounted on the manufacturer's bracket with the top no more than 5 feet above the floor, serviced and tagged by a certified contractor within 12 months or a receipt for a recent purchase, with the owner's manual left for the new occupant
NJ DCA Division of Fire Safety, Bureau of Fire Code Enforcement
| Request received more than 10 business days before the change of occupant | $45.00 |
| Request received 4 to 10 business days before the change of occupant | $90.00 |
| Request received fewer than 4 business days before the change of occupant | $161.00 |